Geometry and inspection
Five-axis access for ports that sit off-axis
Valve bodies and manifolds carry angled ports and intersecting bores. On a 3-axis machine that means multiple fixtures and re-datuming, and every refixture adds position error. A simultaneous 5-axis center reaches those features in one setup, so the port centerline stays true to the main bore.
Inspection follows the drawing, not a habit. We check bore diameters, true position, wall thickness and surface finish, and we keep the records. Reports come on request with the shipment.
- 1
PositionCMM reports on bore-to-bore center distance when the drawing calls for it.
- 2
FinishSeal faces and gasket grooves held at Ra 0.8–1.6 μm.
- 3
CleanlinessParts deburred and cleaned so no nickel swarf reaches your assembly line.